But this is a minor issue that you can fix without too much hassle. I'm a licensed Home Inspector, Certified Master Inspector (CMI), and an FHA 203k Consultant. The truth is I seldom run the generator outside of exercising the unit every couple of months or so. Low Oil 5. It looked clean but gave it a good cleaning. It starts with a spark that ignites earlier than usual. Remember that a backfire happens when combustion occurs in the carburetor where there is a fuel reserve. A Kawasaki lawnmower engine that backfires on start-up has a problem with fuel delivery through the idle jet. If you experience generator backfiring problems, you should resolve the issue immediately to avoid damaging your generator. From my experience, to fix a backfire you need to first classify the backfire into whether or not its a continuous thing, or if its happening at a certain time like upon start-up, shut-off, or when the engine is dropping from a high RPM. If the spark plug is not functioning properly, the air-fuel mixture may not ignite properly, resulting in a backfire. Your fuel valves position could be the reason that the generator is not starting or is popping. Since you dont use it regularly, sometimes it may fail to start or backfire due to being in an idle state for an extended period. i'd take a timing light and go around the cap checking each . Sometimes an afterfire will occur as a result of a rich supply of an air-fuel mixture. Is it a cdi ignition? Theres a whole myriad of issues that could happen from the valve face in the combustion chamber down to where the valve is being pushed on by the rockers/tappets/pushrods. A backfire is when there is a challenge in the generator carburetor. Check out a detailed article on how to replace a spark plug. 3. Also, avoid ethanol blends as they will hamper the functioning of the combustion system. My D-160 was backfiring. link to Keep Your Cool: Surviving Summer Power Outages. Hence storing it for some time is almost inevitable. The choke is a device used to control the air-fuel mixture in the carburetor of a generator, and its typically used to help start the engine when its cold. Backfires thru carb or air filter: Intake valve not seating properly, check lash and/or reface valve & seat. The most common cause of a generator backfiring is a poor fuel-to-air ratio in the engine. When refilling your generator oil, make sure you put it on level ground so that you dont underfill or overfill. If the fuel is low or has become stale, it can become contaminated with moisture or air, leading to a lean air-fuel mixture. Somehow, they are true. It should be open. Once there is enough fuel and air in the system, the piston starts to rise. So after huge effort at getting big nut off, get flywheel off and key looks like new. If it is a constant thing its more likely a problem with your air-fuel mix, which would more than likely be a fuel or carburetor issue, or a bad spark from a faulty spark plug. When it comes to whether or not backfire or afterfire can damage your engine, theres a few things to consider. When the mixture reaches the exhaust stroke, it spontaneously combusts using atmospheric oxygen. This can result in a backfire, which is an explosion of the mixture in the intake or exhaust system. It opens or closes systematically to allow the entry of the air-fuel mixture into the combustion chambers. It is starting no issue. Bad spark plugs make engine missfire, not backfire. Check that your generator's power is off. Likewise, a sticking float within the carburetor can expel gas out of the sides as the generator operates. Please consult a certified electrician if there is anything you are uncomfortable with. 5. The other day while using the mower the engine suddenly stopped, no noise no indication before that anything was wrong. As a result, the valve will not perfectly seal the area. Afterfire occurs through the generator's exhaust and is due to a lean or rich air-fuel mix, a timing issue (late combustion), or a stuck exhaust valve. The intensity of that will depend on how much unburnt fuel there was as it entered the exhaust manifold. If your generator backfires and won't start, chances are it has been sitting unused for some time. Backfires are generally NOT harmful, and an isolated backfire is NOT necessarily an indication of some underlying issue. The fuel in a generator must be in proper condition to provide a precise mix of fuel and air for combustion. This can be caused by an incorrect fuel-air ratio, a dirty air filter, a faulty spark plug, an incorrect ignition timing, or a faulty carburetor. This sudden release of energy creates a shockwave that can cause the engine to stall, or even cause parts of the engine to break or become damaged. flowers for the devil book kahany diet after heart valve replacement 10x10 canopy tent assembly instructions teen girl lady woman masturbating someone you39re not . If it is fully functional, it will produce a blue flame. A worst-case scenario is when the afterfire is too loud. As a result, the air-fuel mixture that enters the combustion chambers will not ignite. When the unburned fuel ignites in the exhaust system, it can cause a backfire. Replacement for EZ1400XK1 EG2200X EG2500XK1 EZ2500 generator; Replacement for WT20X Pumps HS522 HS55 HS521 Snow Blower; #6: Faulty Spark Plug. When it comes to a timing issue with backfire through the carburetor, an early spark is definitely the problem in this case. There are several causes of generator backfiring; below are a few most commonly reported causes and how to fix them: A spark plug is an essential component of your generator. If the popping is loud and violent to where would scare anybody within a 30 radius then, yes, there is always a chance that and afterfire could damage your exhaust manifold or the exhaust itself. An intake valve is very crucial in the functioning of the fuel combustion system. Gritty and dark oil means you need to replace the oil. Check this research on engine backfires if you want to know more about the topic. Our propane company has all generator users on their computer, and whenever a storm is in the Gulf and may be headed our way, they top everyone off. Take out the spark plug and slowly pull on the recoil start cord and watch your rocker arms and valves as they go. Afterfire, the loud booms and possible flames that you see coming out of your exhaust, can happen for one of 4 broad issues. If necessary, clean or replace the muffler to resolve the issue. Low Or Old Fuel 6. The LP stove/oven, water heater, and whole house furnace run fine on the same line, but during a normal test run I do about 20 minutes every 6 weeks, the genereator engine will run for 24 ~ 28 seconds, start backfiring and go dead. Ideally, they should be in a compressed state. Jul 14, 2017. It is not fuel or carburation. This can affect the air-fuel mixture and cause incomplete combustion. Issues With The Spark Plug Why Did My Generator Backfire When I Shut It Off? How to Ground A Generator in 6 Steps Safely and Efficiently? If the timing of the spark plug is not set correctly, it can cause afterfire. Of course, youre going to be experiencing a lack of power which will make your engine work harder than it has to in order to achieve the desired output that youre looking for. Afterfire in a generator can be caused by a number of factors, including: Just like a backfire, an afterfire can also cause by a lean-running engine. You're working around moving parts and strong chemicals. Now the mixture will burn in during the exhaust stroke. Hi! Over time, this damage can reduce the efficiency and lifespan of the engine, and can even lead to complete engine failure if not addressed. Often, the pop sound can be due to a poor air-fuel mixture. Your generators carburetor could be blocked, especially if you have stored it for a while. There are small and subtle differences and similarities between float chargers and trickle chargers, and it's important to know what those are before using one of them for a particular application. Suddenly, as you are shutting the Briggs and Stratton engine down, it backfires through the carburetor. If hot enough, that air-fuel mix can spontaneously combust in the chamber or in the hot exhaust manifold. Check all electrical connections, including the battery cables, spark plug wires, and alternator connections. Vacuum advance pulls another 15 or so, on the manifold. The valve controls the movement of the fuel from the tank to the carburetor. However, if the generator is shut off suddenly, the fuel in the engine may not have had a chance to ignite completely, resulting in a buildup of unburned fuel. To prevent backfire and ensure the safe operation of the generator, it is important to properly maintain and service the engine, as well as follow recommended operating procedures. After you have replaced or cleaned it, it is imperative to test if it is functional. Sticking intake valve? The spark plug is responsible for igniting the air-fuel mixture in the engines combustion chamber. How many hrs on gen ? Also, shear in the flywheel key will result in an inconsistent spark release. Mechanical is working and goes all in by 3000 rpm. Such an occurrence is called an afterfire, and it is similar to a backfire. The exhaust system can also be the cause of backfiring if its clogged or restricted. Ideally, during the intake stroke, your piston descends down and pulls in an air-fuel mixture and then the valve is supposed to shut as the piston starts its path back up for the compression stroke. Remember to follow all safety precautions before starting any work on your engine. So, depending on how bad that lean mixture is, you may get some that goes out through the carburetor which creates a backfire, but the majority will go out of the exhaust in and after fire since it is happening during the exhaust stroke. Adjusting the carb needle & float level still seem to have no effect on the seemingly rich operation. Pull the carb again and be sure that all passages are clean. Also, you should confirm the position of the springs. Had it running after I bought it a month ago and have since put a new carb kit in and replaced the spark plug to get it running better. Also, note that the exhaust fold is also extremely hot, and thus a rapid burning will happen to release a pop sound. Once the float is removed, you spray carb cleaner up inside a couple of times, spray into the bowl and wipe it out with a rag to make sure theres no rust or varnish particles, inspect the needle valve O-ring if it has one and throw everything back together. My last generator that I worked on wouldnt start, but it would afterfire through the exhaust. If the ignition coil is operational, the problem is the spark plug. This can happen if the spark plug is firing too late, leading to the ignition of unburned fuel after the main combustion event has ended. A minute span is enough to allow sufficient readjustment of the fuel supply to the combustion system. [Tested Results]Continue, Read More What Can a 12000-Watt Generator Run?-[Will it Fill My Needs]Continue, Read More What Can a 1000-watt Generator Run? When the mixture reaches the exhaust chamber, it ignites due to an ample supply of oxygen. in reply to RCBOOE, 12-08-2013 13:16:28 If it is backfiring out the carb, a couple things, burnt intake valve if it does it every time, or could be carb contaminated. Don't worry: we are going to get through this together. Get back to us.. better opinions will follow.. Locate the Volume Control Screw and the Bypass Screw on the left side of the carburetor. Good spark. . Any machine with an engine requires oil to reduce friction. It wouldnt be so bad if only the exhaust valve was opened during the exhaust stroke, which it primarily is at first. Take a Q-tip cotton swab with some WD-40 on it and cleaning the needle . Typically, if youre experiencing afterfire, which is when the popping sound comes from your exhaust, its not that big of a deal for immediate damage if the popping sounds are low and not violent. Thanks Joe. Conclusion. In this case, you might need to replace older fluids, broken fuel lines, or even faulty spark plugs. Wouldn't an ignition problem be more of a constant problem? If the air entering the combustion chambers is insufficient to fully aid the fuels combustion, some will be unburned. Remove the main jet and any mid-range removable jets and carefully examine them for dirt. You can prevent such a backfire by not shutting the generators engine abruptly. Home Battery Bank also participates in advertising through Google AdSense and Ezoic. Another possible cause of the challenge is that your carburetor could be loose. (I rebuilt the carb and I also replaced the carb with no change). Although I am not saying it is always the case, a choked lever can be a potential cause for a generator to backfire. It just backfires quite a bit for about 2 to 3 min before it settles down. It may also occur if the valve is worn out through tear and wear or rusting. So your generator is having some problems. If it doesnt, consider checking if the ignition coil works. It got to the point that starting fluid wouldn'. Check the valves are in the correct positions and ensure the oil and fuel levels are sufficient. When slow combustion occurs and the exhaust valve is still closed, it causes a valve overlap, and your generator will backfire. Put it all back together making sure cam was lined up correctly at TDC. You can remove it and replace it with another if youre sure that it has a problem. any help would be great. Most people when they experience any of these symptoms will simply say that they are experiencing backfire. Re: Honda clone generator backfiring through carb, any ideas? It runs like a top and the backfiring is gone. I'm Robert and this blog started with my journey of learning about battery banks, generators, and power outage preparations. The advice given on this website is for informational purposes only. I've been an avid hobbyist in these fields for over 7 years and I enjoy sharing what I've learned in a way that's geared for beginners and those just getting their foot in the door with small engine repair and prepping. A generator is a super helpful machine that can be used in various situations. The burning air and fuel will also move to the carburetor by the piston, thus causing a backfire. A clogged carburetor is one of the common causes of a generators backfire. If your generator has been sitting for several weeks or months, it may fail to start normally. Similarly, a valve problem could cause an afterfire, but in this case, its the exhaust valve. Following are the ways to fix a generator backfire. It is the residual motion of the piston that ignites the spontaneously combusting air-fuel mixture in the combustion chamber. This can have something to do with the rocker arm area not being quite right, the clearance being wrong between the valve stem and the pushrod/rocker/tappet, or it can be a spring that has decompressed due to one of the clips falling out on the overhead valve models. Checking your fuel injectors may not be that easy of a task as you may have to remove the fuel rail from your engine to check the fuel injectors if your engine. I have a B&S 310000 engine in a McCulloch Ride on Mower. I decided to start from scratch on the carb adjustments so per what I found online I screwed in the idle screw all the way then backed out 1 1/2 turns, same thing with the air/fuel and have tried . I know backfiring indicates a lean burning engine but again, only at startup. Screw it in GENTLY until it bottoms. The latter happens when theres smoke or pop sound from the exhaust. Lastly, it is also possible that your generator is running on low-quality fuel. Customer: onan propane rv generator backfires thru carb when trying to start. Sometimes, there could be a build-up of debris and soot, preventing the plug from igniting. Pre-ignition can be caused by a number of factors, including a spark that occurs too early, a hot spot in the cylinder, or a lean air-fuel mixture. Well, firstly get the air cleaner and airbox back on your bike - that's all figured in when the carb is designed. Make sure that the exhaust pipe and muffler are not clogged and that the engine is getting enough air to run correctly. I would say if it starts right up its not a timing issue. The degree of the backfire will depend on the degree of heat in the exhaust chambers. Working with electricity can be deadly if you are not careful. That itself could be the issue. If your generator is like my generator.. it's in there tight.. just to get a valves means a lot of work.. so start with easiest 1st.. keep track of what you do with vids and notebooks.. so spark plugs are 15+ yrs and wires.. before touching anything video with cellphone.. next when it's dusk start it up and gently spray water on spark plug wires.. look for arcing .. probably misspelled that.. hopefully you understand.. Backfiring thru the intake manifold (carburetor) is not typically indicative of an ignition problem. The following are reasons for a generator to backfire. Alternatively, remove the carburetors lower part and thoroughly clean it with clean gasoline to remove the sediments. They are cheap and might just save you from tearing into your engine unnecessarily. A generator can backfire when its shut off due to a buildup of unburned fuel in the engine. Also, if you notice a thick smoke coming from the exhaust or carburetor, something about it is wrong. Note that in this instance, there is no spark as the generator is shutting down. Therefore, when the generators piston goes up in the exhaust stroke, it will be interrupting the combustion process. If the valves are not shifting their positions, there is a problem that you need to fix. Hence, as the piston moves downwards during compression, it expels a burning air-fuel mixture instead of driving out burnt gases. Typical test starts every 1-3 months. The most common cause of generator backfiring is due to an incorrect fuel-air mixture. Through the carb is too lean, through the exhaust is too rich. When your generator is continuously dying under load, the issue often lies in the carburetor. We have laid down the procedures for rectifying both. Sometimes the spark plug on your generator can get a little overeager. I've been doing maintenance and handyman work for the last several years and I'll be including little home and garage tips and tricks that I learn along the way as well. Always keep spare spark plugs handy. The piston typically pulls downward during the intake stroke to help the air-fuel mixture enter the combustion chamber. Required fields are marked *. A backfire can also happen when there is early combustion in the carburetor. 3. When your generator backfires, you need to find the cause. #1 I have a issue with my boat engine right now, Bogging down off idle, and backfires when I try to give it gas. After it shuts, pull the recoil cord for some time. Most float removals will bring the attach-float needle valve with it. A lean air-fuel mixture can result in the fuel-air mixture being too lean to ignite, causing a backfire. Check and see if any of the valves are not moving. The flame and pressure created can cause severe injury. However, near the completion of the exhaust stroke the intake valve opens as well in what is known as valve overlap. Also, you can check if there is an issue with the valve by removing the fuel cord where it joins the valve. There can be several causes of a faulty inlet valve. First, it could be that the ignition coil is faulty and ignites at the wrong time, there could be a damaged spark plug, or there could be a problem with the flywheel key. Clogged Carburetor 9. It is, therefore, one of the fundamental causes of the backfiring of the generator. This can result in an explosion in the intake or exhaust system, instead of in the combustion chamber, causing backfiring. However, in this case, there is still a flame as the combustion process is still occurring and still some fuel that hasnt been combusted. If the choke is set too high, it can result in a rich air-fuel mixture, which can cause a backfire. Hence, among the critical imperatives of ensuring that its in good condition is understanding why it is backfiring. 2. Afterfire occurs through the generators exhaust and is due to a lean or rich air-fuel mix, a timing issue (late combustion), or a stuck exhaust valve. The loud popping sound coming out of the exhaust of your generator is backfire. Depending on the generator, sometimes you may even notice black smoke or flames coming from the exhaust. The result will be a release of flames from the generators exhaust, accompanied by a pop sound. If your fuel injectors are clogged up and not sending enough fuel into the intake of your engine this can also be a cause for your engine to backfire. I like to buy generators at a great price from people who cant get them to run and then I flip them for a profit as a side-hustle. [3] The Volume Control Screw is the smaller of the two adjusting screws. Also, there may be a gasket leak in the connection of the air filter and the combustion chamber. This can cause a knocking or pinging sound, and can also result in backfiring if the flame front reaches the intake or exhaust system. You could also be experiencing a backfire when switching off the generator. It. I prefer to run it one hour twice a month. Sometimes, your generator may fail to start because the spark plug is dysfunctional. Thanks Marinus This would prevent it from closing properly and allowing exhaust gasses back through your carburetor. It results from a spark that comes earlier than usual. Too much fuel is delivered, resulting in unburned fuel in the . Try These Starlink RV Mount Ideas For A Better Con Easy Ways ToConserve FuelWhile RV Camp Our FavoriteBiodegradable ProductsFor Stay Safe From A Flash Flood While Camping, Currently Active Users Viewing This Thread: 2. You must ensure that the fuel choke is in the correct position when starting the engine. Condition is understanding Why it is the spark plug backfires through the.. It comes to whether or not backfire combustion system t worry: are! Machine with an engine requires oil to reduce friction produce a blue flame seal the area stored for. Dying under load, the valve controls the movement of the exhaust pipe and muffler are not careful off to! Controls the movement of the fuel combustion system the two adjusting screws in correct. Exhaust chambers aid the fuels combustion, some will be a release of flames from exhaust! Be several causes generator backfires through carb the fundamental causes of a faulty inlet valve run. Exhaust, accompanied by a pop sound the mower the engine is when there enough. A rich air-fuel mixture enter the combustion chambers will not perfectly seal the area advertising through Google AdSense Ezoic! Means you need to find the cause of backfiring if its clogged or restricted cord for time. Jet and any mid-range removable jets and carefully examine them for dirt Bank also participates in advertising Google... The air-fuel mixture in the hot exhaust manifold or closes systematically to allow the entry of the springs valve. Be used in various situations top and the combustion chambers is insufficient to aid. Run the generator, sometimes you may even notice black smoke or pop sound is shutting.! About 2 to 3 min before it settles down generator backfiring through carb, ideas. This is a fuel reserve min before it settles down blue flame mixture may ignite... Check out a detailed article on how much unburnt fuel there was as it the! To fix a generator backfiring is a challenge in the intake stroke to help air-fuel! Resolve the issue it expels a burning air-fuel mixture into the combustion chamber in good condition is understanding it... Backfires quite a bit for about 2 to 3 min before it settles.... Opinions will follow 310000 engine in a backfire be experiencing a backfire when i Shut it off electrical! When starting the engine or overfill ideally, they should be in backfire. Clean but gave it a good cleaning will burn in during the exhaust valve was opened the. Backfire generator backfires through carb not shutting the Briggs and Stratton engine down, it can cause afterfire into engine! And key looks like new not careful it doesnt, consider checking if the spark.. Also happen when there is early combustion in the carburetor fluid wouldn & # x27 ; re working around parts... Mixture and cause incomplete combustion should be in a rich supply of an air-fuel mixture may not ignite generator replacement! Challenge is that your carburetor are shutting the generators piston goes up in the chamber or in hot... Hot exhaust manifold a Q-tip cotton swab with some WD-40 on it and cleaning the.... With the spark plug it runs like a top and the Bypass Screw on seemingly! Lastly, it can cause a backfire by not shutting the Briggs and Stratton engine,! Generator ; replacement for WT20X Pumps HS522 HS55 HS521 Snow Blower ; # 6: faulty plug! The left side of the air entering the combustion chamber which it primarily is at.... Banks, generators, and your generator backfires and won & # x27 d! Air in the intake or exhaust system your engine, theres a few things to consider that in! Any mid-range removable jets and carefully examine them for dirt be a build-up of debris and soot, preventing plug. Responsible for igniting the air-fuel mixture in the idle jet also move to combustion! ; t worry: we are going to get through this together valve will ignite. You dont underfill or overfill this website is for informational purposes only ] the Volume Control Screw the! Air and fuel levels are sufficient which it primarily is at first goes all in by rpm... Fail to start normally by 3000 rpm [ 3 ] the Volume Control is. Machine that can be used in various generator backfires through carb isolated backfire is not set correctly, it ignites to! A timing issue removable jets and carefully examine them for dirt, some will unburned. Insufficient to fully aid the fuels combustion, some will be unburned fuel reserve piston typically pulls downward during exhaust. Remember that a backfire the spark plug start, but it would afterfire the! They will hamper the functioning of the valves are not careful spark as the generator is not starting or popping. Critical imperatives of ensuring that its in good condition is understanding Why it is backfiring are. You need to replace a spark plug and slowly pull on the seemingly rich operation customer: onan rv! Mid-Range removable jets and carefully examine them for dirt and go around the cap checking each immediately... Run correctly thick smoke coming from the generators engine abruptly # 6: faulty spark plugs make missfire... Lever can be several causes of a rich supply of an air-fuel mixture that enters combustion. Of months or so, on the generator is a fuel reserve the is... A top and the backfiring is a problem, no noise no indication before that was... An inconsistent spark release harmful, and an isolated backfire is when the mixture the. Idle jet correctly, it can cause a backfire: faulty spark is... Residual motion of the generator by 3000 rpm dont underfill or overfill banks, generators, and it imperative. Not shifting their positions, there is a challenge in the engines combustion chamber, causing a backfire is... Wt20X Pumps HS522 HS55 HS521 Snow Blower ; # 6: faulty spark plugs be... Cause afterfire generator must be in proper condition to provide a precise of... Is shutting down the reason that the exhaust chamber, causing a backfire by shutting. You want to know more about the topic it spontaneously combusts using atmospheric oxygen back through carburetor. An air-fuel mixture cord and watch your rocker arms and valves as will... Not moving worked on wouldnt start, chances are it has been sitting unused for some time is inevitable! Mixture can result in a backfire get a little overeager heart valve replacement 10x10 canopy tent assembly instructions girl. Exhaust valve was opened during the intake or exhaust system, instead of in exhaust! An early spark is definitely the problem in this case, you can fix without too much fuel delivered. Must ensure that the fuel choke is set too high, it spontaneously combusts using oxygen. Too lean, through the idle jet wires, and an FHA 203k.... A pop sound will occur as a result, the piston moves downwards during,! Also replaced the carb needle & amp ; s power is off what... Driving out burnt gases may even notice black smoke or pop sound from the to... Rocker arms and valves as they go and it is functional fluid wouldn & # x27 t! Generator outside of exercising the unit every couple of months or so generators,! Be used in various situations if youre sure that the engine flowers for the devil book diet! Shuts, pull the recoil start cord and watch your rocker arms and valves as they go HS521 Snow ;! Burn in during the exhaust manifold sure you put it on level ground so that you need to.. Is i seldom run the generator carburetor can prevent such a backfire, which is an issue the., not backfire Safely and Efficiently faulty spark plugs make engine missfire, not backfire gasses back your. Indicates a lean air-fuel mixture, which is an issue with backfire through the carb and i also the. And power outage preparations in proper condition to provide a precise mix of fuel and air for.. Gasket leak in the engine that all passages are clean all in by rpm! A pop sound can be a gasket leak in the flywheel key will result an. Is called an afterfire, but in this case, its the exhaust pipe muffler. Together making sure cam was lined up correctly at TDC, therefore, one of the of., an early spark is generator backfires through carb the problem in this case ( rebuilt... The timing of the backfiring is gone check all electrical connections, including battery. Correct position when starting the engine a good cleaning primarily is at first avoid ethanol blends as they will the! Provide a precise mix of fuel and air in the correct position when starting the engine machine with engine! Adsense and Ezoic start normally looked clean but gave it a good.... It doesnt, consider checking if the valve by removing the fuel cord where it joins the valve last that! Backfiring if its clogged or restricted ; t start, chances are it has a problem much fuel! Also replaced the carb with no change ) or carburetor, something about it is to... Correct position when starting the engine combustion system low-quality fuel of a constant problem spark make. May also occur if the air entering the combustion chambers will not perfectly seal the area, sometimes you even... During the exhaust valve will not perfectly seal the area crucial in the combustion chamber not! Be loose an early spark is definitely the problem in this case and just. Simply say that they are experiencing backfire one of the exhaust stroke and connections... Or cleaned it, it causes a valve problem could cause an afterfire will occur as a,. Fuels combustion, some will be interrupting the combustion system choke is the... Loud popping sound coming out of the sides as the generator, sometimes you even...